B03 Foundation Plan

Structural Foundation Footing Plan

Shows up loads the exterior walls and center wall

Create a foundation section sketch describing the following variables

A, the footing depth below average grade
B, wall footing width
C, column footing width (if applicable)

Utilize the soil boring report and soil load capacity table to design your foundation.
boring report /soil load table

  • Snow load of 20 pounds per square feet (psi) [or roof live load]
  • Roof dead load of 12 psi
  • Floor live load of 40 psi
  • Floor dead load of 12 psi
  • 45″ (820mm) Frost line depth [US case studies]

Submittal:
submit BOTH the pdf and the dwg files.
DWG files and xrefs (etransmit)
Combine the individual pdf pages into 1 file.

All digital files must be submitted in the following format:
Course number semester/year_Professor initials _Project Name_ Student Name (file number)
For example: ARCH2331_ SP24_AA_A01Logo_BFuller (01)